Controller · FANUC

Connect FANUC Power Mate i and Power Motion i

Power Mate i and Power Motion i-A are FANUC motion controls read with the same FOCAS drivers as the CNC series. FOCAS2 covers Power Motion i-A (PMi-A); commercial FOCAS drivers list Power Mate i. Softing edgeConnector and SDEX list Power Motion i-A among supported controls.

At a glance

Native protocolsFOCAS over Ethernet / HSSB
Default portTCP 8193
LibraryFOCAS2 (PMi-A) or FOCAS1 (Power Mate i)
GatewaysSofting edgeConnector / SDEX (PMi-A)

Connection paths

OPC UA via gatewayAlternative

Softing lists Power Motion i-A.

Licences and options

ItemOption / part numberPaid?Note
FOCAS2 libraryA02B-0207-K737PaidCovers PMi-A
FOCAS1 libraryA02B-0207-K732PaidCovers other series

Ports

PortProtocolNote
8193TCPFOCAS default

Software versions

  • FOCAS2: FS30i/31i/32i/35i, FS0i-D/F and PMi-A.

Data you can read

  • Program: running main program number and name, program comment, current block and sequence number
  • Status: mode, run state, emergency stop, alarm state, operator messages
  • Feed and spindle: feedrate and spindle overrides, actual feed and spindle speed, spindle load
  • PMC (ladder) areas such as R, D, G, F, X, Y, availability depending on the model

Setting it up

  1. Pick the Ethernet portUse the embedded Ethernet port (connector CD38A on the CNC unit) or an Ethernet / Fast Ethernet board if fitted. On the setting screen the active device must be the embedded port, not the memory card slot.
  2. Set the address on the CNCSYSTEM → [ETHER BOARD] or [EMBED PORT] (shown as ETHPRM / EMBDD on some screens) → [COMMON]: IP address, subnet mask, router. Use a fixed address agreed with plant IT.
  3. Set the FOCAS portSame screen → [FOCAS2]: TCP port 8193 is the usual default (allowed range 5001 to 65535). Leave the UDP port at 0 and the time interval at 0 for FOCAS2 use.
  4. Install the FOCAS library on the collectorFOCAS client software needs FANUC's FOCAS library: A02B-0207-K732 (FOCAS1, Ethernet) or A02B-0207-K737 (FOCAS2, Ethernet and HSSB), bought from a FANUC distributor. Commercial drivers will not run without it.
  5. Test from the plant networkOpen TCP 8193 from the collector to the CNC, connect with your driver and read a harmless value first: program number, mode, part count. Then add the rest of the tags.

Troubleshooting

SymptomLikely causeFix
Driver connects to nothing, CNC answers pingFOCAS function not enabled, or the wrong port number in the driverCheck the [FOCAS2] TCP port on the CNC screen and confirm with the builder that the FOCAS Ethernet function is enabled.
Connection refused when a second PC connectsClient limit of the port in useEmbedded Ethernet is meant for few clients (one PC recommended); an Ethernet board accepts more and a Fast Ethernet board the most. Use one collector and share its data instead of letting every tool open its own connection.
Driver installed, project will not runFOCAS library DLLs missing or wrong bitnessInstall the FANUC library (K732 or K737). Commercial OPC drivers use the 32-bit DLLs (FWLIB32.DLL, FWLIBE1.DLL); file names must be in capitals.

Traps to avoid

  • Axis and program functions vary with what the builder configured; test each tag before relying on it.

Connectors that support this control

ProductVendorTypeOutputs
Kepware Server — Fanuc Focas Ethernet / HSSB driversVelotic (formerly PTC Kepware)OPC server / driverOPC UA, OPC DA, A&E, SuiteLink
TOP Server — Fanuc Focas 1&2 Ethernet for CNCsSoftware ToolboxOPC server / driverOPC UA, OPC DA, SuiteLink
edgeConnector (840D, FANUC CNC)SoftingGatewayOPC UA 1.04, MQTT 3.1/3.1.1/5
SDEX SuiteSoftingGatewayOPC UA, MQTT, REST
fanuc-driverLadder99 (open source, Apache-2.0)Open sourceMQTT JSON, Sparkplug B, InfluxDB, MTConnect SHDR

CNC connector directory →

Sources

Facts on this page come from these documents, opened on 27 October 2026.

  1. Software Toolbox — FAQ 1323 (FOCAS1 vs FOCAS2)
  2. Velotic (Kepware) — Fanuc Focas Ethernet driver
  3. Softing — edgeConnector

Last verified 27 October 2026 against vendor documentation. OPC UA Connect is an educational resource published by TEEPTRAK; it is not affiliated with the OPC Foundation, the MTConnect Institute or any control maker.