Which protocol for which machine

Start from the control you have, not from the protocol you like. The control decides what is native, what needs a licence and what needs a gateway.

ControlConnection pathsNoteGuide
SINUMERIK 840D sl, 828D or ONENative OPC UA with the Access MyMachine /OPC UA licenceRichest data and methods; licence per controlOpen →
SINUMERIK 840D sl without the licence, or 840D powerlineS7 gateway that serves OPC UA (uaGate 840D, IBH Link UA, dataFEED)No Siemens runtime licence per Softing; powerline needs an MPI/PROFIBUS adapterOpen →
HEIDENHAIN TNC 620, TNC 640 or TNC7OPC UA NC Server (options 56–61) or HEIDENHAIN DNC (option 18)OPC UA is cross-platform; one option per connected applicationOpen →
HEIDENHAIN iTNC 530, TNC 320/128HEIDENHAIN DNC (port 19000 on iTNC 530)No OPC UA NC Server listed for these controlsOpen →
Any FANUC i-seriesFOCAS over Ethernet (TCP 8193), directly or through a FOCAS-to-OPC UA gatewayFOCAS is the native interface; no on-CNC OPC UA server documentedOpen →
Haas NGCMTConnect on port 8082 (enable through HFO), or Q-commands via Setting 143Native agent on the controlOpen →
Haas ClassicRS-232 Q-commands via a serial device server; I/O if Setting 143 is missingNo Ethernet data interfaceOpen →
Mazak SmoothMTConnect on the control (licence file from Mazak)Mazak's preferred methodOpen →
Okuma OSP-PFree Okuma MTConnect agent; THINC API for developersFree; OPC UA not documented by OkumaOpen →
Mitsubishi M8 / M8VNC Machine Tool Connector (OPC UA + umati model) or MTConnect Adapter on a PCNo OPC UA or MTConnect on the CNC itselfOpen →
Brother D00OPC UA (parameter 0235)Native serverOpen →
DMG MORI with CELOSIoTconnector, or CELOS MTConnect (port 15404)Builder box covers FANUC, Siemens and HEIDENHAIN underneathOpen →
No network interface, or interface lockedDiscrete I/O or non-intrusive current sensorsState and counts only, but works on any machine of any ageOpen →

MTConnect · OPC UA · FOCAS · umati · I/O

MTConnectOPC UAFOCASumatiI/O
DirectionRead onlyRead, write, methodsRead and writeRead, some methods (per facet)Read only
Data modelStandard machine-tool vocabularyDepends on the server; standard only with a companion specFANUC-specificStandard machine-tool model (OPC 40501-1)Whatever you wire
TransportHTTP (agent), SHDR from adapterOPC UA binary over TCP, usually 4840FANUC library over TCP 8193 or HSSBOPC UADigital inputs
SecurityNone built into the protocol: isolate the networkCertificates, signing, encryption, user rightsNetwork isolationOPC UA securityPhysical
Typical costFree to paid agent depending on builderCNC licence (Siemens, HEIDENHAIN) or gatewayFANUC library + driverDepends on control and serverI/O module and wiring

Last verified 27 October 2026 against vendor documentation. OPC UA Connect is an educational resource published by TEEPTRAK; it is not affiliated with the OPC Foundation, the MTConnect Institute or any control maker.