Controller · Brother

Connect Brother CNC-D00 (SPEEDIO)

Brother's CNC-D00 lists OPC UA among its NC functions. Integrator documentation shows the server enabled by communication parameter 0235 "OPC UA server function" = Valid, with security set by 0236 and 0237 (0 = no user or password, 1 to 5 = RSA/AES levels with authentication). Brother does not state whether OPC UA is standard or an option.

At a glance

Native protocolOPC UA server (parameter 0235)
Other interfacesEthernet, USB, RS232C optional
FieldbusCC-Link, PROFIBUS DP, DeviceNet, PROFINET, EtherNet/IP slave
Endpointopc.tcp://<ip>:4840 in integrator example

Connection paths

Proprietary Ethernet register protocolAlternative

Litmus Brother Speedio Ethernet driver, TCP 10000, requires Remote Operation

Licences and options

ItemOption / part numberPaid?Note
OPC UA server functionNot stated by BrotherUnknown

Ports

PortProtocolNote
4840TCPOPC UA (integrator example, not stated as fixed)
10000TCPBrother Ethernet register protocol (Litmus)

Data you can read

  • Through OPC UA: node list not published
  • Through the register protocol: program numbers, operation and power-on times, counters, state, mode, alarms, doors, overrides, G/M-code groups, coordinates up to 8 axes, feed, spindle, tools, logs, PLC devices

Setting it up

  1. Open the communication parametersDATABANK → 7. Communication parameter.
  2. Set the network0202 DHCP, 0203 IP address (12 digits, no dots, e.g. 172022003034), 0204 mask; 0004 Display slave command alarm = No; 0216 Restrict Ethernet access = No.
  3. Enable OPC UA0235 OPC UA server function = Valid; 0236 Security communication for client = 2: Type2; 0237 security level (0 = none, 1–5 = RSA/AES with authentication).
  4. CheckMONITR → 3. Communication monitor shows "Ethernet (OPC UA)".

Troubleshooting

SymptomLikely causeFix
Client cannot log inSecurity level and credentials mismatchAlign 0237 with the client policy; level 0 means no authentication, use it only on an isolated network.

Traps to avoid

  • Security level 0 disables authentication.

Connectors that support this control

ProductVendorTypeOutputs
MachineMetrics EdgeMachineMetricsMonitoring softwareCloud
Litmus EdgeLitmusEdge platformBroker integrations
WebAccess/CNCAdvantechMonitoring softwareOPC UA/DA, Modbus, REST

CNC connector directory →

Not published by the vendor. We could not find these in vendor documentation. Ask the control or machine maker before you rely on them.
  • Whether OPC UA is a paid option
  • D00 OPC UA node list

Questions engineers ask

How do I enable OPC UA on a Brother D00?

Communication parameter 0235 = Valid, then set security in 0236 and 0237, and check the communication monitor.

Sources

Facts on this page come from these documents, opened on 27 October 2026.

  1. Brother — CNC-D00
  2. MachineMetrics support — Brother D00 (OPC UA)
  3. Litmus Edge — Brother Speedio Ethernet (Gen1)

Last verified 27 October 2026 against vendor documentation. OPC UA Connect is an educational resource published by TEEPTRAK; it is not affiliated with the OPC Foundation, the MTConnect Institute or any control maker.