Controller · HEIDENHAIN

Connect HEIDENHAIN TNC 640

TNC 640 supports the HEIDENHAIN OPC UA NC Server from NC software 34059x-10, with one option (56 to 61) per connected application, and HEIDENHAIN DNC with option 18. DNC clients connect on TCP 19003 and receive on 19010 to 19015 (Cybus guidance); TNC 640 needs four passwords for full DNC access.

At a glance

Native protocolsOPC UA NC Server; HEIDENHAIN DNC; LSV-2
OPC UAFrom 34059x-10, options 56–61
DNCOption 18 required
DNC ports19003 to control, 19010–19015 back
DataProduction, tools, messages, PLC

Connection paths

HEIDENHAIN DNCAlternative

Windows clients, option 18.

LSV-2Legacy

File and status access through LSV-2 tools; vendor-licensed protocol.

Licences and options

ItemOption / part numberPaid?Note
OPC UA NC ServerOptions 56–61PaidPer application
HEIDENHAIN DNCOption 18PaidCheck with MOD + SIK

Ports

PortProtocolNote
19003TCPDNC to control
19010–19015TCPDNC back to the agent
9000TCPUsed by the Litmus Edge HEIDENHAIN 640 driver

Software versions

  • OPC UA NC Server: 34059x-10 or later
  • Tool data application: software 17
  • OPC Router DNC plug-in lists TNC 640 34059x-01 (DNC 1.5.1)

Data you can read

  • Machine messages: program end and abort, maintenance messages, custom messages raised from the NC program
  • Production data: running and interrupted jobs and their durations
  • NC program transfer and program control
  • Tool data (for example from a presetter)
  • Counters, program durations, temperatures, fill levels, pallet magazine status
  • PLC values published by the machine builder, with units and value ranges
  • ExecutionMode: MANUAL, MDI, RPF, SINGLESTEP, AUTOMATIC, HANDWHEEL
  • ProgramStatus: IDLE, RUNNING, STOPPED, INTERRUPTED, FINISHED, ERROR, NOT_SELECTED

Setting it up

  1. Check the software and optionsOPC UA NC Server needs NC software TNC7 81762x-16, TNC 640 34059x-10 or TNC 620 81760x-08 or later, and one software option per connected application: options 56 to 61 (SIK) or 3-02-1 (SIK2). A 90-day trial is available.
  2. Run the HEIDENHAIN Connection AssistantThe wizard on the control sets up the server, the certificates and the user mapping.
  3. Use certificate-based usersThe default authentication is an X.509 v3 user certificate; username and password can be allowed (NC.OpcUaPwAuth), optionally only on the machine network (NC.OpcUaPwAuthOnlyMachineNet).
  4. Connect the clientUse Basic256Sha256 with SignAndEncrypt. The programming station (free demo software) includes the full OPC UA NC Server, so you can develop the client before touching the machine.
  5. Grant write rights deliberatelyChanging counters via OPC UA needs the NC.RemoteOperator role.
  6. Check option 18HEIDENHAIN DNC (option 18, SIK2 3-03-1) is required on TNC 640 and later; integrator documentation says it is not required on iTNC 530. Check with MOD and the SIK menu.
  7. Allow external accessEnable external access (MOD > External access / CfgAccessCtrl). On iTNC 530, REMOTE.PERMISSION in TNC:\TNC.SYS controls it.
  8. Open the portsiTNC 530 / TNC 426: TCP 19000. TNC 640: TCP 19003 to the control and 19010 to 19015 back to the client agent (Cybus guidance).
  9. Install the clientDNC clients use HEIDENHAIN's RemoTools SDK (Windows COM), so the collector runs on Windows.

Troubleshooting

SymptomLikely causeFix
DNC client times outReturn ports 19010–19015 blockedAllow them from the control to the agent PC.
Access denied over DNCExternal access not permitted or passwords missingEnable external access and supply the PLC, user, table and system passwords.

Traps to avoid

  • DNC requires a Windows host for the RemoTools SDK COM component.

Connectors that support this control

ProductVendorTypeOutputs
StateMonitorHEIDENHAINControl or machine makerERP/MES job interface
ConnectwareCybusEdge platformMQTT, OPC UA server
Litmus EdgeLitmusEdge platformBroker integrations
OPC Router + HEIDENHAIN plug-ininrayMiddlewareOPC UA, MQTT, REST, SQL, SAP
WebAccess/CNCAdvantechMonitoring softwareOPC UA/DA, Modbus, REST
pyLSV2Open source (MIT)Open sourcePython
Predator MDCPredator SoftwareMonitoring softwareSQL / MES / ERP

CNC connector directory →

Not published by the vendor. We could not find these in vendor documentation. Ask the control or machine maker before you rely on them.
  • OPC UA port on vendor pages

Questions engineers ask

Does the TNC 640 need option 18?

For HEIDENHAIN DNC access, yes. For the OPC UA NC Server, options 56 to 61 apply instead.

Sources

Facts on this page come from these documents, opened on 27 October 2026.

  1. HEIDENHAIN — OPC UA NC Server brochure
  2. HEIDENHAIN — TNC options and accessories brochure
  3. MachineMetrics support — HEIDENHAIN DNC connectivity
  4. Cybus — Connecting a machine via HEIDENHAIN DNC
  5. OPC Router — HEIDENHAIN plug-in
  6. Litmus Edge — HEIDENHAIN 640 Ethernet driver
  7. pyLSV2 — protocol notes

Last verified 27 October 2026 against vendor documentation. OPC UA Connect is an educational resource published by TEEPTRAK; it is not affiliated with the OPC Foundation, the MTConnect Institute or any control maker.

CNC Connectivity Field Kit
Take the Field Kit to site
Every controller on one spreadsheet, with ports, licences, commissioning checklists and a firewall request template. Free with an engineer account.