Controller · HEIDENHAIN

Connect HEIDENHAIN iTNC 530

iTNC 530 has no OPC UA NC Server in HEIDENHAIN's documentation; it is read through HEIDENHAIN DNC on TCP 19000, and integrator documentation says option 18 is not required on the iTNC 530. LSV-2 tools also work on it. DMG MORI's IoTconnector lists iTNC 530 HSCI and iTNC 530².

At a glance

OPC UA NC ServerNot listed by HEIDENHAIN
DNC portTCP 19000
Option 18Not required (integrator documentation)
LSV-2Supported by LSV-2 tools

Connection paths

LSV-2Alternative

pyLSV2 or commercial LSV-2 packages; file and status access.

Builder boxVendor product

DMG MORI IoTconnector on DMG MORI machines.

Licences and options

ItemOption / part numberPaid?Note
HEIDENHAIN DNCOption 18Not required on iTNC 530 per integrator docsCheck SIK with password Opt18

Ports

PortProtocolNote
19000TCPDNC

Software versions

  • OPC Router plug-in: iTNC 530 NC 340420-06, 340422-01, 340480-01, 34049x-03, 60642x-01 (DNC 1.6.1)

Data you can read

  • ExecutionMode: MANUAL, MDI, RPF, SINGLESTEP, AUTOMATIC, HANDWHEEL
  • ProgramStatus: IDLE, RUNNING, STOPPED, INTERRUPTED, FINISHED, ERROR, NOT_SELECTED
  • Program name, run time, overrides, errors, tool status
  • Tool and pocket tables, file system, PLC data (depending on the client)

Setting it up

  1. Check option 18HEIDENHAIN DNC (option 18, SIK2 3-03-1) is required on TNC 640 and later; integrator documentation says it is not required on iTNC 530. Check with MOD and the SIK menu.
  2. Allow external accessEnable external access (MOD > External access / CfgAccessCtrl). On iTNC 530, REMOTE.PERMISSION in TNC:\TNC.SYS controls it.
  3. Open the portsiTNC 530 / TNC 426: TCP 19000. TNC 640: TCP 19003 to the control and 19010 to 19015 back to the client agent (Cybus guidance).
  4. Install the clientDNC clients use HEIDENHAIN's RemoTools SDK (Windows COM), so the collector runs on Windows.

Troubleshooting

SymptomLikely causeFix
Connection refused on 19000External access disabledSet REMOTE.PERMISSION in TNC:\TNC.SYS and allow external access in MOD.

Traps to avoid

  • pyLSV2's author warns it can damage the control and is not meant for production use; a lockout parameter blocks most operations beyond file handling.

Connectors that support this control

ProductVendorTypeOutputs
OPC Router + HEIDENHAIN plug-ininrayMiddlewareOPC UA, MQTT, REST, SQL, SAP
ConnectwareCybusEdge platformMQTT, OPC UA server
StateMonitorHEIDENHAINControl or machine makerERP/MES job interface
pyLSV2Open source (MIT)Open sourcePython
WebAccess/CNCAdvantechMonitoring softwareOPC UA/DA, Modbus, REST
Predator MDCPredator SoftwareMonitoring softwareSQL / MES / ERP

CNC connector directory →

Questions engineers ask

Does iTNC 530 support OPC UA?

Not natively according to HEIDENHAIN's OPC UA NC Server documentation. Use HEIDENHAIN DNC (port 19000) or a gateway that serves OPC UA from DNC.

Sources

Facts on this page come from these documents, opened on 27 October 2026.

  1. MachineMetrics support — HEIDENHAIN DNC connectivity
  2. Cybus — Connecting a machine via HEIDENHAIN DNC
  3. OPC Router — HEIDENHAIN plug-in
  4. pyLSV2 — protocol notes
  5. DMG MORI — IoTconnector release (23 Dec 2020)
  6. HEIDENHAIN — OPC UA NC Server brochure

Last verified 27 October 2026 against vendor documentation. OPC UA Connect is an educational resource published by TEEPTRAK; it is not affiliated with the OPC Foundation, the MTConnect Institute or any control maker.