Controller · Haas

Connect Haas Classic Control (pre-2017)

Classic Haas controls share data over RS-232 with Q-commands when Setting 143 is present on the I/O page; a serial-to-Ethernet server such as a Moxa NPort puts them on the network. If Setting 143 is absent, the machine cannot share data and is connected through discrete I/O.

At a glance

PathRS-232 Q-commands via serial server
Key setting143 Machine Data Collect
Serial38400 baud, XON/XOFF; parity and data bits differ between sources
FallbackDiscrete I/O

Connection paths

Discrete I/OFallback

When Setting 143 is missing.

Ports

PortProtocolNote
4001TCPTypical serial-server local port

Software versions

  • Classic control = machines before 2017 (RS-232 settings on the I/O page)

Data you can read

  • Q-commands: Q100 serial number, Q101 software version, Q102 model, Q104 mode, Q200 total tool changes, Q201 tool in use, Q300 power-on time, Q301 motion time, Q303 last cycle time, Q304 previous cycle time, Q402 M30 parts counter #1, Q403 M30 parts counter #2, Q500 program, status and parts in one reply, Q600 macro variable read

Setting it up

  1. Check Setting 143On the I/O page; if absent, use I/O.
  2. Set serialSetting 11 baud 38400, 12 parity, 13 stop bit 1, 14 XON/XOFF, 37 data bits. Sources differ on parity (EVEN vs NONE) and data bits (7 vs 8): match what your control accepts.
  3. Serial serverTCP server mode, local port 4001, FIFO on, limit connections.

Troubleshooting

SymptomLikely causeFix
Garbled repliesParity or data-bit mismatchTry the alternative parity/data-bit pair documented by integrators.

Traps to avoid

  • Change the serial server's default password.

Connectors that support this control

ProductVendorTypeOutputs
NPort serial device serversMoxaGatewayTCP
MTConnect Agent for HaasTrakHound (GPL-2.0)Open sourceMTConnect
Predator MDCPredator SoftwareMonitoring softwareSQL / MES / ERP
MachineMetrics EdgeMachineMetricsMonitoring softwareCloud
WebAccess/CNCAdvantechMonitoring softwareOPC UA/DA, Modbus, REST

CNC connector directory →

Not published by the vendor. We could not find these in vendor documentation. Ask the control or machine maker before you rely on them.
  • Official Haas serial defaults (haascnc.com could not be opened)

Sources

Facts on this page come from these documents, opened on 27 October 2026.

  1. MachineMetrics support — Haas serial machine data collection
  2. MachineMetrics support — Is my Haas Next Gen, Classic, serial or I/O?
  3. Advantech — WebAccess/CNC Haas connection guide
  4. TrakHound — MTConnect Agent for Haas

Last verified 27 October 2026 against vendor documentation. OPC UA Connect is an educational resource published by TEEPTRAK; it is not affiliated with the OPC Foundation, the MTConnect Institute or any control maker.