By machine builder
Connecting DMG MORI machines
DMG MORI machines run CELOS on top of FANUC, Siemens or HEIDENHAIN controls (and MAPPS on Mori Seiki heritage machines). DMG MORI's IoTconnector, standard on new machines since 2020, provides OPC UA, MTConnect and MQTT; retrofit and flex variants cover older and third-party machines. On CELOS with Siemens, MTConnect must be purchased; on CELOS with FANUC it is usually pre-installed.
Controls found on DMG MORI machines
| Control | Native protocol | Licence on the CNC | Default port |
|---|---|---|---|
| DMG MORI CELOS and IoTconnector | OPC UA, MTConnect, MQTT (IoTconnector) | IoTconnector / IoT Connectivity | 15404 |
| FANUC Series 30i / 31i / 32i / 35i (A, B, B Plus) | FOCAS2 (Ethernet) | Standard on B Plus; FOCAS library on the PC | 8193 |
| SINUMERIK 840D sl | OPC UA server | 6FC5800-0AP67-0YB0 | 4840 |
| HEIDENHAIN TNC 640 | OPC UA NC Server; DNC | Options 56–61; DNC 18 | 19003 (DNC) |
| HEIDENHAIN iTNC 530 | HEIDENHAIN DNC; LSV-2 | Option 18 not required (integrators) | 19000 |