Connecting DMG MORI machines

DMG MORI machines run CELOS on top of FANUC, Siemens or HEIDENHAIN controls (and MAPPS on Mori Seiki heritage machines). DMG MORI's IoTconnector, standard on new machines since 2020, provides OPC UA, MTConnect and MQTT; retrofit and flex variants cover older and third-party machines. On CELOS with Siemens, MTConnect must be purchased; on CELOS with FANUC it is usually pre-installed.

Controls found on DMG MORI machines

ControlNative protocolLicence on the CNCDefault port
DMG MORI CELOS and IoTconnectorOPC UA, MTConnect, MQTT (IoTconnector)IoTconnector / IoT Connectivity15404
FANUC Series 30i / 31i / 32i / 35i (A, B, B Plus)FOCAS2 (Ethernet)Standard on B Plus; FOCAS library on the PC8193
SINUMERIK 840D slOPC UA server6FC5800-0AP67-0YB04840
HEIDENHAIN TNC 640OPC UA NC Server; DNCOptions 56–61; DNC 1819003 (DNC)
HEIDENHAIN iTNC 530HEIDENHAIN DNC; LSV-2Option 18 not required (integrators)19000