Controller · Hurco

Connect Hurco WinMax

Integrator documentation lists Hurco among builders with MTConnect agents on the control (ports 7878 and 5000; may need enabling by the distributor; on the Windows-based control, test locally at 127.0.0.1:5000/current). Hurco's own pages we opened say nothing about MTConnect or OPC UA licensing.

At a glance

Native protocolMTConnect agent (integrator documentation)
Ports5000 agent, 7878 adapter
ActivationMay need the distributor

Connection paths

Discrete I/OFallback

Licences and options

ItemOption / part numberPaid?Note
MTConnect on WinMaxAsk the Hurco distributorUnknown

Ports

PortProtocolNote
5000HTTPMTConnect agent
7878TCPSHDR adapter

Data you can read

  • MTConnect items defined by the agent's device file

Setting it up

  1. Ask the distributorEnable MTConnect if needed.
  2. Test locallyOn the control, open 127.0.0.1:5000/current.
  3. Open the portAllow TCP 5000 from the collector.

Connectors that support this control

ProductVendorTypeOutputs
MTConnect cppagentMTConnect Institute (Apache-2.0)Open sourceMTConnect REST, MQTT
MachineMetrics EdgeMachineMetricsMonitoring softwareCloud
DataXchangeScytec (Minitab)Monitoring software—
DatanomixDatanomixMonitoring software—

CNC connector directory →

Not published by the vendor. We could not find these in vendor documentation. Ask the control or machine maker before you rely on them.
  • Hurco option name and price
Related

Sources

Facts on this page come from these documents, opened on 27 October 2026.

  1. MachineMetrics support — MTConnect builders incl. Hurco

Last verified 27 October 2026 against vendor documentation. OPC UA Connect is an educational resource published by TEEPTRAK; it is not affiliated with the OPC Foundation, the MTConnect Institute or any control maker.