Controller · HEIDENHAIN
Connect HEIDENHAIN CNC PILOT 620/640 and MANUALplus 620
HEIDENHAIN lathe controls CNC PILOT 620/640 and MANUALplus 620 are not listed for the OPC UA NC Server; DNC tools cover them (OPC Router: CNC PILOT 640 with DNC 1.3.1, CNC PILOT 620 and MANUALplus 620 with DNC 1.5.1).
At a glance
| OPC UA NC Server | Not listed |
|---|---|
| DNC | Supported by DNC tools |
Connection paths
HEIDENHAIN DNCRecommended
LSV-2Alternative
pyLSV2 tested on programming stations
Licences and options
| Item | Option / part number | Paid? | Note |
|---|---|---|---|
| HEIDENHAIN DNC | Option 18 | Paid | Confirm availability per control |
Software versions
- CNC PILOT 640 688946-01 / 688947-01 (DNC 1.3.1)
- CNC PILOT 620 688945-01; MANUALplus 620 548328-05 / 54843x-01 (DNC 1.5.1)
Data you can read
- ExecutionMode: MANUAL, MDI, RPF, SINGLESTEP, AUTOMATIC, HANDWHEEL
- ProgramStatus: IDLE, RUNNING, STOPPED, INTERRUPTED, FINISHED, ERROR, NOT_SELECTED
Setting it up
- Check option 18HEIDENHAIN DNC (option 18, SIK2 3-03-1) is required on TNC 640 and later; integrator documentation says it is not required on iTNC 530. Check with MOD and the SIK menu.
- Allow external accessEnable external access (MOD > External access / CfgAccessCtrl). On iTNC 530, REMOTE.PERMISSION in TNC:\TNC.SYS controls it.
- Open the portsiTNC 530 / TNC 426: TCP 19000. TNC 640: TCP 19003 to the control and 19010 to 19015 back to the client agent (Cybus guidance).
- Install the clientDNC clients use HEIDENHAIN's RemoTools SDK (Windows COM), so the collector runs on Windows.
Connectors that support this control
| Product | Vendor | Type | Outputs |
|---|---|---|---|
| OPC Router + HEIDENHAIN plug-in | inray | Middleware | OPC UA, MQTT, REST, SQL, SAP |
| pyLSV2 | Open source (MIT) | Open source | Python |
Not published by the vendor. We could not find these in vendor documentation. Ask the control or machine maker before you rely on them.
- OPC UA or MTConnect on these lathe controls
Sources
Facts on this page come from these documents, opened on 27 October 2026.
Last verified 27 October 2026 against vendor documentation. OPC UA Connect is an educational resource published by TEEPTRAK; it is not affiliated with the OPC Foundation, the MTConnect Institute or any control maker.