Controller · Brother

Connect Brother CNC-C00 and B00 (SPEEDIO)

Brother's C00/B00 specification pages list Ethernet but not OPC UA or MTConnect. Data is read over the machine's HTTP and FTP interfaces (integrator method) or Brother's Ethernet register protocol on TCP 10000. Firmware 12.026 or later is recommended for reliable reporting.

At a glance

OPC UA / MTConnectNot listed
InterfacesHTTP + FTP; register protocol TCP 10000
Firmware12.026+ recommended

Connection paths

Register protocolAlternative

TCP 10000, Remote Operation enabled.

Ports

PortProtocolNote
10000TCPRegister protocol
HTTP / FTPTCPStandard ports implied, not stated

Software versions

  • Firmware 12.026 or later recommended; earlier may not report properly

Data you can read

  • HTTP/FTP: part count, alarms, program number, program header (mixed or FTP mode)
  • Register protocol: same set as D00 above

Setting it up

  1. Open settingsDATA BANK → Communication Parameter → Ethernet/FTP tab.
  2. Set alarms and accessDisplay slave command alarm = 0; on firmware 12+, Restrict Ethernet Access = 0.
  3. Create FTP userSet FTP user and password on the control for mixed or FTP mode.
  4. SaveF0 Completion Mode > Cancel W/Save Changes.

Troubleshooting

SymptomLikely causeFix
Production monitoring incompleteHTTP-only mode has no program headerUse mixed (HTTP + FTP) mode.

Traps to avoid

  • FTP-only mode is not recommended where FTP is already used for program transfer.

Connectors that support this control

ProductVendorTypeOutputs
MachineMetrics EdgeMachineMetricsMonitoring softwareCloud
Litmus EdgeLitmusEdge platformBroker integrations
WebAccess/CNCAdvantechMonitoring softwareOPC UA/DA, Modbus, REST

CNC connector directory →

Not published by the vendor. We could not find these in vendor documentation. Ask the control or machine maker before you rely on them.
  • A Brother MTConnect option or "CNC Net" product (not found on Brother pages)

Sources

Facts on this page come from these documents, opened on 27 October 2026.

  1. Brother — S500Bd1/S700Bd1 specifications
  2. MachineMetrics support — Brother C00 (HTTP/FTP)
  3. Litmus Edge — Brother Speedio Ethernet (Gen1)

Last verified 27 October 2026 against vendor documentation. OPC UA Connect is an educational resource published by TEEPTRAK; it is not affiliated with the OPC Foundation, the MTConnect Institute or any control maker.

CNC Connectivity Field Kit
Take the Field Kit to site
Every controller on one spreadsheet, with ports, licences, commissioning checklists and a firewall request template. Free with an engineer account.